Härtemesser, Härte, Shore A 15s | Farbe | Empfohlene maximale Betriebs-temperatur °C (°F) | Zugefestigkeit Pounds per Square Inch (psi) (M Pa) |
Maximale Dehnung % | Zugde- formations test % |
Reißfestigkeit lb-f/in (kN/m) | Druckver- formungstest ** Konstante Durchbiegung, B |
Versprödungs-temperatur | Dichte | Wasserabsorption % | |
ASTM-Verfahren |
D2240-91
|
D412-92
|
D412-92
|
D412-92
|
D1004-93
|
D395-89
|
D746-79
|
D792-91
|
D570-81
|
||
Tygon®R-3603 Vacuum |
55
|
Transparent
|
74(165)
|
1650
(114)
|
450
|
107
|
125
(22)
|
61
|
-50°C
(-58°F)
|
118
|
024
|
GSR |
55
|
Transparent
|
74(165)
|
1650
(114)
|
450
|
107
|
125
(22)
|
61
|
-50°C
(-58°F)
|
118
|
024
|
GA |
45
|
Rot
|
70(158)
|
1305
(9)
|
400
|
23
|
80
(14)
|
28
|
-56°C
(-72°F)
|
113
|
028
|
Tygon® 3350 |
50*
|
Durchscheinend
|
200(392)
|
1450
(100)
|
770
|
13
|
200
(35)
|
7
|
-80°C
(-112°F)
|
114
|
011
|
Tygon® 3370 IB |
70*
|
Durchscheinend
(zwischen Geflecht) |
160(320)
|
1200
(83)
|
500
|
21
|
250
(44)
|
3
|
-80°C
(-112°F)
|
122
|
022
|
Tygon® 2275 |
72
|
Transparent
|
52(125)
|
2000
(138)
|
700
|
187
|
220
(39)
|
84
|
-78°C
(-108°F)
|
090
|
000
|
Tygon® 2275 IB |
72
|
Transparent
|
52(125)
|
2000
(138)
|
700
|
187
|
220
(39)
|
84
|
-78°C
(-108°F)
|
090
|
<001
|
Versilic® |
60
|
Transparent
|
200(392)
|
1305
(9)
|
300
|
8
|
100
(18)
|
36
|
-60°C
(-80°F)
|
116
|
006
|
Tygon® S-50-HL |
66
|
Transparent
|
74(165)
|
2000
(138)
|
350
|
76
|
165
(29)
|
53
|
-48°C
(-55°F)
|
120
|
014
|
Tygon® S-54-HL |
80
|
Transparent
|
85(185)
|
2700
(186)
|
320
|
33
|
305
(53)
|
34
|
-31°C
(-25°F)
|
124
|
011
|
Tygon® B-44-4X |
65
|
Transparent
|
74(165)
|
2100
(145)
|
450
|
78
|
200
(35)
|
62
|
-44°C
(-47°F)
|
121
|
015
|
* 1-zweiter Durchgang
** Test bei 70°C (158°F) während einer Dauer von 22 Stunden
Härtemesser, Härte, Shore A 15s | Farbe | Empfohlene maximale Betriebs-temperatur °C (°F) | Zugefestigkeit Pounds per Square Inch (psi) (M Pa) |
Maximale Dehnung % | Zugde- formations test % |
Reißfestigkeit lb-f/in (kN/m) | Druckver- formungstest ** Konstante Durchbiegung, B |
Versprödungs-temperatur | Dichte | Wasserabsorption % | |
ASTM - Verfahren |
2240-91
|
|
|
D412-92
|
D412-92
|
D412-92
|
D1004-93
|
D395-89
|
D746-79
|
D792-91
|
D570-81
|
Tygon®B-44-4X I.B. |
65
|
Durchscheinend
(zwischen Geflecht) |
74(165)
|
2100
(145)
|
450
|
78
|
200
(35)
|
62
|
-44°C
(-47 °F)
|
121
|
015
|
Norprene®A-60-F |
61
|
Beige
|
135(275)
|
1000
(69)
|
375
|
57
|
120
(21)
|
30
|
-60°C
(-75°F)
|
098
|
030
|
Norprene®A-60-F I.B. |
61
|
Creme
|
135(275)
|
1000
(69)
|
375
|
57
|
120
(21)
|
30
|
-60°C
(-75°F)
|
098
|
030
|
PharMed®Tubing |
64
|
Dunkelgelb
|
135(275)
|
1050
(72)
|
375
|
47
|
128
(22)
|
32
|
-73°C
(-99°F)
|
097
|
030
|
Tygon®LFL |
56
|
Transparent
|
74(165)
|
1550
(107)
|
380
|
44
|
122
(21)
|
64
|
-54°C
(-65° F)
|
116
|
018
|
Tygon®R-1000 |
40
|
Transparent
|
52(125)
|
1200
(83)
|
375
|
73
|
52
(9)
|
57
|
-75°C
(-103°F)
|
112
|
030
|
Fluran®F-5500-A |
60*
|
Schwarz
|
204(400)
|
1400
(93)
|
300
|
13
|
100
(18)
|
37
|
-51°C
(-60°F)
|
190
|
023
|
Tygon®F-4040-A |
57
|
GelbDurchscheinend
|
74(165)
|
1821
(125)
|
312
|
50
|
167
(29)
|
65
|
-35°C
(-37'F)
|
126
|
049
|
Tygon®2075 |
72
|
Transparent
|
52(125)
|
2000
(138)
|
700
|
187
|
220
(39)
|
84
|
-78°C
(-108°F)
|
090
|
001
|
Tygon®R-3400 |
64
|
Schwarz
|
74(165)
|
2250
(15.5)
|
350
|
66
|
185
(32)
|
69
|
-21°C
(-5°F)
|
1.31
|
0.19
|
Iso-Versinic® |
60170
|
Schwarz
|
200(392)
|
(9)
|
250
|
9
|
143
(25)
|
22
|
-50°C
(-58°F)
|
1.90
|
0.20
|
Norprene®A-60-G |
61
|
Schwarz
|
135(275)
|
1000
(6.9)
|
375
|
57
|
120
(21)
|
30
|
-60°C
(-75°F)
|
0.98
|
0.30
|
Tygothane®C-210-A |
82*
|
Transparent
|
93(200)
|
6050
(41.7)
|
500
|
98
|
475
(83)
|
68
|
-73°C
(-100°F)
|
1.19
|
1.12
|
Tygothane®C-544-A I.B. |
85*
|
Durchsichtig
transparent
|
82(180)
|
5000
(34.5)
|
400
|
45
|
350
(61.3)
|
19
|
-73°C
(-100°F)
|
1.12
|
1.80
|
Butyl |
65
|
Weiß
|
100(212)
|
1160
(8)
|
600
|
80
|
130
(22.8)
|
64
|
-40°C
(-40°F)
|
1.45
|
0.15
|
Nitrile |
65
|
Schwarz
|
100(212)
|
1160
(8)
|
600
|
30
|
100
(17.5)
|
64
|
-10°C
(-14°F)
|
1.45
|
0.81
|
Neoprene |
50
|
Schwarz
|
100(212)
|
1088
(7.5)
|
450
|
28
|
60
(10.5)
|
31
|
-38°C
(-36°F)
|
1.55
|
1.23
|
Tygon®SE-200 |
67***
|
Transparent
|
77(170)
|
2000
(13.8)
|
350
|
76
|
165
(29)
|
53
|
-40°C
(-40°F)
|
1.45
|
<0.01
|
Chemfluor®367 |
58D*
|
Durchscheinend
|
204(400)
|
2300
(15.8)
|
300
|
N.A.
|
N.A.
|
N.A.
|
-196°C
(-320°F)
|
2.15
|
<0.03
|
Chemfluor®FEP |
55D*
|
Translucent
|
204(400)
|
2600
(17.9)
|
275
|
N.A.
|
N.A.
|
N.A.
|
-73°C
(-100°F)
|
2.17
|
<0.01
|
Chemfluor®PFA |
60D*
|
Translucent
|
260(500)
|
2500
(17.2)
|
300
|
N.A.
|
NA
|
N.A.
|
-196"C
(-320°F)
|
2.17
|
<0.03
|
Chemfluor®PTFE |
58D*
|
Translucent
|
288(550)
|
2650
(18.3)
|
250
|
N.A.
|
N.A.
|
N.A.
|
-268°C
(-450°F)
|
2.18
|
<0.01
|
* 1-zweiter Durchgang
** Test bei 70°C (158°F) während einer Dauer von 22 Stunden - Versilic/Iso-Versinic
22 Std. bei 175°C Butyl/Nitrile 22 Std. bei 100°C
*** Durometer gemessen Außenmantel